Application
Nominal sizes
Parts and characteristics
Construction features
Material and surfaces
Standards and guidelines
Maintenance
Nominal sizes | 100 – 400 mm |
Volume flow rate range | 10 – 750 l/s or 36 – 2700 m³/h |
Thermal output | 0.25 – 18 kW |
Maximum hot water temperature | 150 °C |
Maximum water-side operating pressure | 10 bar |
Water-side differential pressure | 0.3 – 12 kPa |
Air-side static differential pressure | 5 – 80 Pa |
Technical data of the heat exchanger
Basic units: TVR, RN and VFC (TEST)
NS | qv | Δpst | PWW 50/40, te = 16 °C | PWW 70/55, te = 16 °C | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
l/s | m³/h | Pa | Φ [kW] | ta [°C] | qm [kg/h] | Δpv [kPa] | Φ [kW] | ta [°C] | qm [kg/h] | Δpv [kPa] | |
100 | 10 | 36 | 5 | 0.25 | 36.1 | 21 | 0.3 | 0.40 | 48.5 | 23 | 0.5 |
100 | 20 | 72 | 10 | 0.38 | 31.3 | 33 | 0.4 | 0.62 | 41.2 | 36 | 0.6 |
100 | 30 | 108 | 15 | 0.47 | 28.8 | 41 | 0.5 | 0.79 | 37.5 | 46 | 0.7 |
100 | 40 | 144 | 25 | 0.55 | 27.2 | 48 | 0.6 | 0.95 | 35.2 | 55 | 0.8 |
100 | 45 | 162 | 30 | 0.58 | 26.5 | 51 | 0.7 | 1.02 | 34.4 | 59 | 1 |
125 | 18 | 65 | 5 | 0.36 | 32 | 31 | 0.3 | 0.58 | 42.2 | 34 | 0.5 |
125 | 35 | 126 | 20 | 0.51 | 27.9 | 44 | 0.5 | 0.87 | 36.2 | 51 | 0.8 |
125 | 50 | 180 | 40 | 0.62 | 26 | 53 | 1 | 1.09 | 33.8 | 64 | 1 |
125 | 65 | 234 | 60 | 0.7 | 24.8 | 61 | 1.2 | 1.3 | 32.3 | 76 | 1.3 |
125 | 75 | 270 | 80 | 0.76 | 24.2 | 66 | 1.5 | 1.44 | 31.6 | 84 | 1.5 |
160 | 28 | 101 | 5 | 0.69 | 36.1 | 60 | 1 | 1.17 | 49.9 | 68 | 1 |
160 | 50 | 180 | 10 | 1.05 | 33.1 | 91 | 2 | 1.83 | 45.8 | 107 | 3 |
160 | 70 | 252 | 15 | 1.35 | 31.7 | 117 | 4 | 2.32 | 43 | 135 | 4 |
160 | 95 | 342 | 25 | 1.7 | 30.6 | 147 | 5 | 2.85 | 40.4 | 166 | 6 |
160 | 115 | 414 | 35 | 1.94 | 29.7 | 168 | 7 | 3.23 | 38.8 | 188 | 7 |
200 | 45 | 162 | 5 | 0.97 | 33.6 | 84 | 2 | 1.69 | 46.5 | 98 | 2 |
200 | 80 | 288 | 20 | 1.49 | 31.2 | 129 | 4 | 2.54 | 41.8 | 148 | 5 |
200 | 115 | 414 | 35 | 1.94 | 29.7 | 168 | 7 | 3.23 | 38.8 | 188 | 7 |
200 | 150 | 540 | 55 | 2.29 | 28.4 | 199 | 9 | 3.37 | 36.8 | 223 | 10 |
200 | 180 | 648 | 80 | 2.57 | 27.6 | 223 | 11 | 4.3 | 35.4 | 251 | 12 |
250 | 70 | 252 | 5 | 1.53 | 33.8 | 133 | 1 | 2.67 | 47 | 155 | 1 |
250 | 125 | 450 | 15 | 2.35 | 31.3 | 203 | 2 | 4.14 | 43 | 242 | 3 |
250 | 180 | 648 | 25 | 3.1 | 30 | 269 | 3 | 5.29 | 39.9 | 308 | 4 |
250 | 235 | 846 | 40 | 3.76 | 29 | 326 | 5 | 6.29 | 37.8 | 367 | 5 |
250 | 290 | 1044 | 60 | 4.29 | 28.1 | 372 | 6 | 7.2 | 36.2 | 420 | 7 |
315 | 115 | 414 | 5 | 2.5 | 33.7 | 217 | 1 | 4.41 | 47.2 | 257 | 1 |
315 | 200 | 720 | 15 | 3.82 | 31.5 | 331 | 2 | 6.66 | 43.1 | 388 | 3 |
315 | 285 | 1026 | 25 | 5.02 | 30.4 | 436 | 4 | 8.45 | 40.1 | 493 | 4 |
315 | 375 | 1350 | 40 | 6.05 | 29.1 | 525 | 5 | 10.11 | 37.9 | 589 | 6 |
315 | 460 | 1656 | 60 | 6.89 | 28.2 | 597 | 7 | 11.52 | 36.4 | 672 | 7 |
400 | 185 | 666 | 5 | 4.02 | 33.7 | 348 | 2 | 7.08 | 47.2 | 413 | 2 |
400 | 325 | 1170 | 15 | 6.24 | 31.6 | 542 | 3 | 10.55 | 42.4 | 615 | 4 |
400 | 465 | 1674 | 30 | 8.06 | 30.1 | 699 | 5 | 13.4 | 39.5 | 781 | 6 |
400 | 605 | 2178 | 50 | 9.54 | 28.8 | 827 | 7 | 15.89 | 37.4 | 927 | 8 |
400 | 750 | 2700 | 75 | 10.92 | 27.9 | 947 | 9 | 18.22 | 35.8 | 1062 | 10 |
Φ: Thermal output
PWW: Pumped hot water heating system, flow temperature/return temperature
te: Inlet airflow temperature
ta: Outlet airflow temperature
qv: Volume flow rate
qm: Mass flow rate
Δpv: Water-side differential pressure
Δpst: Static differential pressure
Circular hot water heat exchangers for reheating the airflow in ventilation and air conditioning systems. Dimensions suitable for VAV terminal units TVR and CAV control units RN and VFC. Spigot with lip seal for ducts according to EN 1506 or EN 13180. Casing air leakage according to EN 15727, class D.
Materials and surfaces
Technical data
Sizing data
WL | / | 160 |
---|---|---|
| | | | |
1 | 2 |
Order example: WL/160
Type | WL – Hot water heat exchanger |
Nominal size [mm] | 160 |
Condividi pagina
Consiglia questa pagina
Consiglia questa pagina inviando un link via e-mail.
Condividi pagina
Grazie per la tua condivisione!
La tua segnalazione è stata inviata e dovrebbe arrivare a breve.
Contatti
Siamo qui per te
Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01
Contatti
Grazie per il tuo messaggio!
Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01
Contatti
Siamo qui per te
Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01
Contatti
Grazie per il tuo messaggio!
Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01