00131940_0
Expansion module EM-TRF


00132390_0
EASYLAB controller TCU3


00131607_0
EASYLAB adapter module TAM


00131940_0
00132390_0
00131607_0

EM-TRF

FOR CONNECTING TROX UNIVERSAL CONTROLLERS AS WELL AS EASYLAB CONTROLLERS AND TAM ADAPTER MODULES TO THE MAINS SUPPLY

Extension module enables direct connection to a 230 V AC mains supply without additional power supply units

  • Double connection terminals for supply voltage 230 V AC

  • Electric plug connection to the main PCB
  • Extension module is integrated into the housing of the EASYLAB or TROX UNIVERSAL controller


General information

Application

  • Enables direct connection of the TCU3 controller board to a 230 V AC mains supply without additional power supply units for the following components:
  • EASYLAB controller and its adapter module TAM
  • TROX UNIVERSAL controller
  • Power supply of the TCU3 including connected modules, actuators and control units
  • Suitable for factory installation or retrofitting


Special features

  • Ready-to-install and matched to the fixing points in the basic housing
  • Double connection terminals for supply voltage 230 V AC
  • Simple electrical connection of extension module and TCU3 controller board with connector plug
  • Simple wiring of switchable fume cupboard lighting in conjunction with the EM-LIGHT extension module for EASYLAB fume cupboard controller


Parts and characteristics

  • Mains transformer 230 V AC (primary), 24 V AC (secondary)
  • Board connector plug for connection to the TCU3 controller board
  • Safety latch for controller housing TCU3


Construction features

  • Dimensions and fixing suitable for the controller housing of an EASYLAB or TROX UNIVERSAL controller or EASYLAB TAM
  • Fixing with screws
  • Double connection terminals for easy wiring of the supply voltage 230 V AC


Commissioning

  • When ordering a flow rate control unit with EASYLAB, TROX UNIVERSAL controller or EASYLAB TAM - specifying order option T: EM-TRF installed, connected and ready for operation
  • For retrofitting: Installation required


Important: After installation of the EM-TRF, the TCU3 controller board must no longer be supplied with 24 V


Information technique

Function, Technical data, Specification text, Order code, Related products

  • FUNCTION
  • TECHNICAL DATA
  • SPECIFICATION TEXT
  • ORDER CODE
EM-TRF 00134256_0
① Primary fuse
② Connection terminals for supply voltage
③ PCB connector plugs for connection to the TCU3 controller board




This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme.

Extension module for EASYLAB and TROX UNIVERSAL controllers as well as EASYLAB adapter module TAM. Enables direct connection of the TCU3 controller PCB to a supply voltage of 230 V AC. The extension module contains a transformer whose secondary voltage (extra-low voltage 24 V) corresponds to the supply voltage of the controllers and connected modules.

Special features

  • Ready-to-install and matched to the fixing points in the basic housing
  • Double connection terminals for supply voltage 230 V AC
  • Simple electrical connection of extension module and controller board TCU3 by means of connector plug
  • Simple wiring of switchable fume cupboard lighting in conjunction with the EM-LIGHT extension module for EASYLAB fume cupboard controller


Technical data

  • Supply voltage: 230 V AC ±10 %, 50/60 Hz
  • Power consumption depending on the equipment of the respective control component and in particular the type of actuator used on the TROX UNIVERSAL or EASYLAB controller
  • Up to 9 VA for EASYLAB adapter module
  • Up to 29 VA for individual or room controller without control unit
  • Up to 33 VA for room controller with control unit
  • Up to 35 VA for fume cupboard controller with control panel
  • Up to 40 VA for controllers with all extensions
  • Double connection terminals: Power cross-section up to 2.5 mm²
  • Protection level: IP 20

1 Product

EM-TRF Extension module for 230 V AC mains supply

Note:

This is the order code for retrofitting the expansion module into a VAV terminal unit with EASYLAB or TROX UNIVERSAL control component or a TROX adapter module TAM.

Generally, the extension module is ordered with the VAV terminal unit via the order code of the basic unit under the section Expansion modules with the order code T set.


 

Installation details

  • INSTALLATION DETAILS
EM-TRF-installation

Volume flow controller TVR with EASYLAB control component 1 Controller TCU3 in housing2 EM-TRF 3 Volume flow control unit

Important note

If the EM-TRF extension module is installed, the TCU3 controller board must not longer be supplied with 24 V.

Commissioning with factory preparation

When ordering the EASYLAB or TROX UNIVERSAL controller with EM-TRF extension module, the module is factory-fitted, connected and immediately ready for operation.

Installation and commissioning for retrofitting

  • Disconnect the EASYLAB or TROX UNIVERSAL controller from the power supply
  • Disconnect 24 V supply
  • Install the EM-TRF extension module in the controller housing and connect it to the TCU3 controller board
  • Mounting the safety latch on the outside of the controller housing
  • Connecting the 230 V mains supply
  • Extension module is automatically recognised the next time it is switched on

Téléchargements

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Partager la page

Recommander cette page

Vous avez la possibilité de recommander cette page en partageant le lien.

Les champs marqués d'une étoile (*) sont obligatoires.

Contact

Merci pour votre message !

Votre recommandation a été envoyée et sera bientôt reçue par le destinataire.

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande.
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Pièce jointe (max. 10MB)

Les champs marqués d'une étoile (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Contact

Nous sommes à votre disposition

Veuillez préciser votre message et le type de demande.
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01

Pièce jointe (max. 10MB)

Les champs marqués d'une étoile (*) sont obligatoires.

Contact

Merci pour votre message !

Votre message a été envoyé et sera traité dans les plus brefs délais.
Notre département de traitement des demandes prendra contact avec vous dès que possible.
Pour les questions d'ordre général concernant les produits ou services, vous pouvez aussi nous appeler :
Tel.: +41 26 425 59 00 | Fax: +41 26 425 59 01