img_pro_001639.png
FHD – Construction without centre mullion

img_pro_001750.png
Spigot with fixed baffle plate

Spigot with fixed baffle plate

img_pro_001633.png
Spigot with adjustable baffle plate

Spigot with adjustable baffle plate

img_pro_001634.png
Spigot with damper blade

Spigot with damper blade

doc_graphic_000009.png
Tested to VDI 6022

Conforms to VDI 6022

img_pro_001639.png
img_pro_001750.png
img_pro_001633.png
img_pro_001634.png
doc_graphic_000009.png

FHD

For the most critical requirements in clean room areas


 

Final filters for the separation of suspended particles, suitable for industrial, research, medical, and pharmaceutical applications

  • Filter classes E11, H13, H14, U15
  • Performance factory tested to EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to different constructions
  • Filter hood available in various sizes and the usual grid sizes
  • Automatic filter scan test for all filters from filter class H14
  • Meets the hygiene requirements of VDI 6022

 

Optional equipment and accessories

  • Mechanism for volume flow rate setting

 

 

 


Introduction

Application


  • Mini Pleat filter panels with hood, type FHD, for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in clean room systems with controlled air cleanliness and airflow.
  • Particulate filters: Final filters for the most critical requirements of air cleanliness and sterility in areas such as production, research, medicine, pharmaceuticals industry, and nuclear engineering

Special characteristics
  • Ideal pleat geometry of the filter medium
  • Low-turbulence airflow on the downstream side
  • Leakage test, standard for all particulate filters of classes H13, H14, U15

Nominal sizes
  • B × H × D [mm]

Description

Filter classes

Filter groups

  • EPA according to EN 1822
  • HEPA according to EN 1822
  • ULPA according to EN 1822


Filter classes

  • E11 
  • H13
  • H14
  • U15

Options

  • Spigot diameter
  • PD: Protection grid on the downstream side
  • SD: Stainless steel protection grid on the downstream side
  • SPD: Perforated stainless steel face plate on the downstreamside
  • APD: Perforated aluminium face plate on the downstreamside
  • WS: Without seal▪FND: Flat seal on the downstream side
  • OT: Oil mist test (only for filter classes H13, H14)
  • OTC: Oil mist test with certificate (only for filter classes H13,H14)
  • ST: Scan test (only for filter classes H13, H14, U15


Construction

  • Without centre mullion, spigot with fixed baffle plate
  • D: Centre mullion with pressure measurement point on the downstream side, spigot with fixed baffle plate
  • R: Centre mullion with pressure measurement point on the downstream side, spigot with adjustable baffle plate for volume flow rate balancing
  • V: Centre mullion with pressure measurement point on the downstream side, spigot with damper blade for volume flow rate balancing


Construction features

  • Hood with top entry circular spigot
  • Spigot diameter available in commercial sizes
  • Some constructions are fitted with an optional flat seal on the downstream side
  • Protection grid on downstream side: expanded metal grid or stainless steel
  • Perforated stainless steel or aluminium face plate on the downstream side

Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glassfibre papers, pleated
  • Spacers provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made from extruded aluminium sections
  • Hood with spigot made of galvanised sheet steel

  • Standards and guidelines
  • Testing of particulate filters to EN 1822-1 and ISO 29463-2 toISO 29463-5 (EPA, HEPA and ULPA filters): standards forthe testing of filtration performance in the factory, particlecounting method using a liquid test aerosol
  • Uniform classification of particulate filters according toefficiency, using a test aerosol whose average particle sizelies within the minimum efficiency (MPPS)
  • Particulate filters are classified according to the valuesdetermined for the local filtration efficiency and the overallfiltration efficiency as EPA (filter classes E10, E11, E12),HEPA (filter classes H13, H14) or ULPA (filter classes U15,U16, U17)
  • Hygiene conformity: VDI 6022, VDI 3803, DIN 1946 Part 4,ÖNORM H 6020, SWKI VA 104-01 and SWKI 99-3 and EN16798


Technical information

TECHNICAL DATA, QUICK SIZING, SPECIFICATION TEXT, ORDER CODE, Related products

  • TECHNICAL DATA
  • SPECIFICATION TEXT
  • ORDER CODE

Filter class according to EN 1822E11H13H14U15
Efficiency [%] according to EN 1822> 95> 99.95> 99.995> 99.9995
Nominal face velocity [m/s]0.820.820.450.45
Initial differential pressure [Pa] at nominal face velocity125250125145
Recommended final differential pressure [Pa]300600600300
Max. operating temperature [°C]80808080
Maximum relative humidity [%]100100100100

① Nominal size ② Nominal volume flow rate ③ Initial differential pressure ④ Filter area ⑤ Weight


Specification text


Mini Pleat filter panels with hood, type FHD, for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in clean room systems with controlled air cleanliness and airflow. Use as particulate filters, i.e. main or final filters, for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering. Mini Pleat filter panels with hood, consisting of an extruded aluminium frame, filter medium, and a hood with top entry circular spigot; filter media made from high-quality, moisture-resistant glass fibre papers with spacers made of thermoplastic hot-melt adhesive. Low initial differential pressure due to ideal pleat position and largest possible filter area. Filter hood available in various sizes and the usual grid sizes, filter classes E11, H13, H14 and U15. Optional flat seal and protection grid on the downstream side. Choice of expanded metal, powder-coated (RAL 9010) protection grid, stainless steel protection grid, or perforated plate made of stainless steel or aluminium. Mini Pleat filter panels from filter class H14 are subjected to an automatic filter scan test. Mini Pleat filter panels with hood FHD hygienically conform to VDI 6022.


Special characteristics


  • Ideal pleat geometry of the filter medium
  • Low-turbulence airflow on the downstream side
  • Leakage test, standard for all particulate filters of classes H13, H14, U15


Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glassfibre papers, pleated
  • Spacers provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made from extruded aluminium sections
  • Hood with spigot made of galvanised sheet steel


Construction

  • Without centre mullion, spigot with fixed baffle plate
  • D: Centre mullion with pressure measurement point on the downstream side, spigot with fixed baffle plate
  • R: Centre mullion with pressure measurement point on the downstream side, spigot with adjustable baffle plate for volume flow rate balancing
  • V: Centre mullion with pressure measurement point on the downstream side, spigot with damper blade for volume flow rate balancing


Sizing data

• Filter class [EN 1822]
• Volume flow rate [m³/h]
• Initial differential pressure [Pa]
• Nominal size [mm]




FHDH13D / 1220 × 610 × 140×313 / PD / FND / ST
||||||||
12345678

1 Type
FHD Mini Pleat filter panel with hood
 
2 Filter class
E11 Particulate filter according to EN 1822
H13 Particulate filter according to EN 1822
H14 Particulate filter according to EN 1822
U15 Particulate filter according to EN 1822
 
3 Construction
No entry: without centre mullion; spigot with fixed baffle plate
D centre mullion with pressure measurement point on the downstream side, spigot with fixed baffle plate
R Centre mullion with pressure measurement point on the downstream side, spigot with adjustable baffle plate for volume flow rate balancing
V Centre mullion with pressure measurement point on the downstream side, spigot with damper blade for volume flow rate balancing
 
4 Nominal size [mm]
B × H × T
 
5 Spigot diameter [mm]
D
 
6 Protection grid
PD Protection grid on the downstream side
SD Stainless steel protection grid on the downstream side
SPD Perforated stainless steel face plate on the downstream side
APD Perforated aluminium face plate on the downstream side
 
7 Seal
WS without seal
FND Flat seal on the downstream side
 
8 Testing
No entry: no leakage test
OT Oil mist test (only for filter classes H13, H14)
OTC Oil mist test with certificate (only for filter classes H13, H14)
ST Scan test (only for filter classes H13/H14/U15)

FHD–H13–D/1220×610×140×313/PD/FND/ST
Filter class H13 Particulate filter according to EN 1822
Construction centre mullion with pressure measurement point on the downstream side, spigot with fixed baffle plate
Nominal size 1220 × 610 × 140 mm
Spigot diameter 313 mm
Protection grid downstream side
Seal Flat seal on the downstream side
Test scan test


Variants, Dimensions

  • VARIANTS
  • DIMENSIONS

Options

  • D: Spigot diameter
  • PD: Protection grid on the downstream side
  • SD: Stainless steel protection grid on the downstream side
  • SPD: Perforated stainless steel face plate on the downstream side
  • APD: Perforated aluminium face plate on the downstream side
  • FND: Flat seal on the downstream side
  • WS: Without seal
  • OT: Oil mist test (only for filter classes H13, H14)
  • OTC: Oil mist test with certificate (only for filter classes H13, H14)
  • ST: Scan test (only for filter classes H13, H14, U15)


B [mm]H [mm]T [mm]Filter classSpigot diameterqv [l/s]qv [m³/h]ΔpA [Pa]kg
305305140E11148762751252,84
457457140E111981726201256,26
305610140E111981535501255,75,5
610610140E11248306110012511,18,1
915610140E11248458165012516,611,1
1220610140E11313611220012522,114
305305140H13148762752502,84
457457140H131981726202506,26
305610140H131981535502505,75,5
610610140H13248306110025011,18,1
915610140H13248458165025016,611,1
1220610140H13313611220025022,114
305305140H14148421501252,84
457457140H14198943401256,26
305610140H14198833001255,75,5
610610140H1424816860512511,18,1
915610140H1424825090012516,611,1
1220610140H14313333120012522,114
305305140U15148421501452,84
457457140U15198943401456,26
305610140U15198833001455,75,5
610610140U1524816860514511,18,1
915610140U1524825090014516,611,1
1220610140U15313333120014522,114

Downloads

informazioni di prodotto

certificati

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Condividi pagina

Consiglia questa pagina

Consiglia questa pagina inviando un link via e-mail.

I campi contrassegnati con (*) sono obbligatori.

Condividi pagina

Grazie per la tua condivisione!

La tua segnalazione è stata inviata e dovrebbe arrivare a breve.


Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Attachment (max. 10MB)

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Attachment (max. 10MB)

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01