00132312_0
Smoke protection damper JZ-RS-G with actuator
00131764_0
JZ-RS with actuator
00132450_0
With TROXNETCOM as an option
00131762_0
JZ-RS with AS-i module
00133733_0
Smoke protection damper, Type JZ-RS, with installation subframe
00132312_0
00131764_0
00132450_0
00131762_0
00133733_0

JZ-RS

To prevent the spreading of smoke

Smoke protection dampers are used in ventilation plant rooms or in ducts to prevent smoke from spreading

  • Casing air leakage to EN 1751, class C
  • Low differential pressure and sound power level
  • Airflow direction is not critical
  • Available in standard sizes and many intermediate sizes


Optional equipment and accessories

  • Duct smoke detector RM-O-VS-D or RM-O-3-D
  • Installation subframe
  • Integration into the central BMS with TROXNETCOM

Application

Application

  • Smoke protection dampers of Type JZ-RS are used in ventilation plant rooms or in ducts to prevent smoke from spreading (according to the German guideline regarding fire protection requirements on ventilation systems, LüAR)
  • For the refurbishment of systems with regard to fire safety
  • Can be triggered by duct smoke detectors with general building inspectorate licence
  • Integration into the central BMS with TROXNETCOM

Special characteristics

  • Low differential pressure and sound power level
  • Aerofoil blades
  • Low-maintenance, robust construction
  • No parts with silicone
  • Available in standard sizes and many intermediate sizes
  • Closed cell side seals meet increased hygiene requirements

Classification

  • Building inspectorate licence Z-78.4-51 from the DIBt, Berlin, Germany
  • Casing air leakage to EN 1751, class C
  • Closed blade air leakage at a differential pressure of 40 Pa = 200 m³/h per m²
  • Long-term testing: 10,000 open/close cycles

Nominal sizes

  • Standard: B = 400 – 2000 mm (in increments of 200 mm), H = 345 – 1995 mm (in increments of 165 mm)
  • R20 sizes: B = 357 – 1998 mm (in R20 increments), H = 357 – 1998 mm (in R20er increments)

Description

Construction

  • Galvanised sheet steel, corner holes on both sides, brass bearings
  • G: Flange holes on both sides

Parts and characteristics

  • Frame
  • Blade
  • Spring return actuator
  • External linkage
  • Travel stop (angle section), side B
  • Side seal, side H

Attachments

  • Installation subframe ER
  • Duct smoke detector
  • TROXNETCOM

Construction features

  • Rectangular casing, welded, material thickness 1.25 mm
  • Blades, material thickness 1 mm, opposed action
  • Flanges on both sides, suitable for duct connection, either flange holes or corner holes
  • Spring return actuator on the 2nd blade (for all sizes)
  • Control input signal from the central BMS or TROXNETCOM
  • External linkage, robust and durable, consisting of the coupling rod and and horizontal arms
  • Blade shafts, Ø12 mm, with notch to indicate the blade position
  • Construction and materials comply with the EU directive and guidelines for use in potentially explosive atmospheres (ATEX)
  • Side seals between the regular blades and the frame
  • Travel stop (angle section) ensures tight closure of the top and bottom blades

Materials and surfaces

  • Casing, blades and travel stop (angle section) made of formed galvanised sheet steel; flanges on both sides with corner holes
  • Blade shafts, drive arm and external linkage made of galvanised steel
  • Side seal made of stainless steel
  • Brass bearings

Standards and guidelines

  • German 'Bau- und Prüfgrundsätze' [Principles of Construction and Testing], 2/84 edition
  • Maintenance standards DIN 31051 and EN 13305

Maintenance

  • Smoke protection dampers and duct smoke detectors must be maintained regularly and must be operational at all times
  • To maintain the normal function of the unit, or to re-instate its normal function, maintenance standards DIN 31051 and EN 13305 must be complied with
  • Smoke protection dampers must be maintained at least every 12 months
  • A maintenance report must be created; documents must be kept for reference
  • Maintenance-free as construction and materials are not subject to wear

Technical information

  • Function
  • Technology
  • Quick sizing
  • SPECIFICATION TEXT
  • ORDER CODE

Functional description

Smoke protection dampers with external linkage have opposed action blades.

An external linkage transfers the synchronous rotational movement from the drive arm to the individual blades.

Even large dampers can be safely opened and closed with this type of linkage.

Opposed action blades close at different speeds since the linkage includes a transverse link.

This facilitates the closing process and reduces the closed blade air leakage.

Nominal sizes357 × 345 to 2000 × 1998 mm
Volume flow rate range200 – 40,000 l/s or 720 – 143,640 m³/h
Maximum static differential pressureUp to 3000 Pa
Operating temperature–20 to 150 °C


Quick sizing – differential pressure and sound power level for JZ-RS

vDamper blade position α
vOPEN/0°20°40°60°80°
vΔpstLWAΔpstLWAΔpstLWAΔpstLWAΔpstLWA
m/sPadB(A)PadB(A)PadB(A)PadB(A)PadB(A)
0.5<5<30<5<30<5<30224425567
1<5<30<5<308388559101082
2<531<535285333574>2000>90
4<546105011068139589>2000>90
6<555225925077>2000>90>2000>90
8861406544083>2000>90>2000>90
101466607069088>2000>90>2000>90


Smoke protection dampers for use in ventilation plant rooms or in ducts to prevent smoke from spreading; frame made from C-sections, with aerodynamically profiled hollow blades and external linkage, spring return actuator, with general building inspectorate licence Z-78.4-51 from the DIBt, Berlin, Germany.

Can be triggered by duct smoke detectors with general building inspectorate licence, e.g. TROX duct smoke detector RM-O-VS-D or RM-O-3-D.

Special characteristics

  • Low differential pressure and sound power level
  • Aerofoil blades
  • Low-maintenance, robust construction
  • No parts with silicone
  • Available in standard sizes and many intermediate sizes
  • Closed cell side seals meet increased hygiene requirements

Materials and surfaces

  • Casing, blades and travel stop (angle section) made of formed galvanised sheet steel; flanges on both sides with corner holes
  • Blade shafts, drive arm and external linkage made of galvanised steel
  • Side seal made of stainless steel
  • Brass bearings

Construction

  • Galvanised sheet steel, corner holes on both sides, brass bearings
  • G: Flange holes on both sides

Technical data
  • Nominal sizes: 357 × 345 to 2000 × 1998 mm
  • Volume flow rate range: 200 to 40,000 l/s or 720 to 143,640 m³/h
  • Acceptable static differential pressure: up to 3000 Pa
  • Operating temperature: –20 to 150 °C

Life cycle assessment
A life cycle assessment is available for the product series in form of an Environmental Product Declaration (EPD) that has been checked and published by a programme holder.

00100953_0

 Type
JZ-RS              Smoke protection damper

 Construction
       No entry: standard construction
G       Flange holes on both sides

Drive side
R       Right side
L       Left side
       (If the drive side is not specified with the order, R will be supplied.)

 

 Nominal size [mm]
       B × H

 Installation subframe
No entry: none
ER       With (only for construction G)

 Attachments
Spring return actuator (power off to close), IP 54
ZF06       24 V AC / DC
ZF07       24 – 240 V AC 
ZF08       24 V AC / DC, with limit switches
ZF09       24 – 240 V AC , with limit switches 
ZF10       24 V AC / DC, with control actuator

 

Downloads

informazioni di prodotto

certificati

manuali d'uso

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Condividi pagina

Consiglia questa pagina

Consiglia questa pagina inviando un link via e-mail.

I campi contrassegnati con (*) sono obbligatori.

Condividi pagina

Grazie per la tua condivisione!

La tua segnalazione è stata inviata e dovrebbe arrivare a breve.


Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Attachment (max. 10MB)

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Contatti

Siamo qui per te

Specifichi il suo messaggio ed il tipo di richiesta
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01

Attachment (max. 10MB)

I campi contrassegnati con (*) sono obbligatori.

Contatti

Grazie per il tuo messaggio!

Il tuo messaggio è stato inviato e sarà processato a breve.
Il nostro dipartimento per la gestione delle richieste ti contatterà appena possibile.
Per domande di carattere generale riguardanti i nostri prodotti o servizi, è possibile contattare:
Tel.: +41 26 425 59 00 | Fax: +41 55 250 73 10 | Fax Fribourg: +41 26 425 59 01